[Downlights] [Uplights] [Outside Lighting] [Address]

Skot logo

Electronic Transformers - Technical Sheet

    • IP40 Insulation class II
    • Fully dimmable with most leading and trailing edge dimmers

 

 

  • 60 Watt

-

Part number 35517

  • 200mm flying leads

Min VA

20

  • Short circuit and overload protection – the transformer will shut off automatically in the case of short circuit or overload, after removing the cause of the short circuit or overload the transformer will start to supply the load again.
  • In the event of over temperature the transformer will cut the load by means of a thermal fuse.
  • VDE approved

Max VA

60

Length

124mm

Width

37mm

Height

27mm

45mm

 

 

  • 105 Watt

-

Part number 35516

  • 200mm flying leads

Min VA

35

  • Short circuit and overload protection – the transformer will shut off automatically in the case of short circuit or overload, after removing the cause of the short circuit or overload the transformer will start to supply the load again.
  • In the event of over temperature the transformer will cut the load by means of a thermal fuse.
  • VDE approved

Max VA

105

Length

124mm

Width

37mm

Height

27mm

45mm

 

 

  • 150 Watt

-

Part number 35518

  • 200mm flying leads

Min VA

50

  • Short circuit and overload protection – the transformer will shut off automatically in the case of short circuit or overload, after removing the cause of the short circuit or overload the transformer will start to supply the load again.
  • In the event of over temperature the transformer will cut the load by means of a thermal fuse.
  • VDE approved

Max VA

150

Length

144mm

Width

43mm

Height

35mm

55mm

 

 

  • 210 Watt

-

Part number 35519

  • 200mm flying leads

Min VA

75

  • Short circuit and overload protection – the transformer will shut off automatically in the case of short circuit or overload, after removing the cause of the short circuit or overload the transformer will start to supply the load again.
  • In the event of over temperature the transformer will cut the load by means of a thermal fuse.
  • VDE approved.

Max VA

210

Length

205mm

Width

49mm

Height

39mm

59mm

  • The total wattage of the lamps must not exceed the wattage of the transformer.
  • The maximum distance between the transformer and the 12 volt lamp must not exceed two metres.
  • The transformer must not be positioned closer than 200mm to the lamp.
  • The transformer must not be positioned near central heating pipes or covered with insulation.
  • All the transformers may be installed with suitable dimming equipment.
  • One 60 watt transformer will operate a 50 watt halogen lamp or 3 x 20 watt 12 volt halogen lamps.
  • One 210 watt transformer will operate 4 x 50 watt 12 volt halogen lamps.
  • Use the same lengths of cable between each lamp and the transformer.
  • The lamps should be wired in parallel.

 


Skot Transformers Ltd., Upper Colwall, Malvern, Worcestershire, WR13 6PL, UK.
Phone: (national) 01684 569104   (international) +44 1684 569104
Fax: (national) 01684 565766   (international) +44 1684 565766
E-mail: sales@skot.co.uk
Registered in England. Registered No. 2596093
Value Added Tax Registered No. 589103716

[Home] [Downlights] [Uplights] [Outside Lighting] [Top]